Table 31: Switch Properties dialog box messages (Continued)

Message

User action

Out of range domain ID specified.

Verify that all information is valid and retry the

 

configuration change. Consult the

 

documentation for valid configurations.

 

Valid domain IDs must be in the range 1 to

 

239, and must be unique within a fabric. If the

 

fabric contains Switch with E_Port switches, all

 

domain IDs must be in the same range of

 

sixteen values: 1…16, 17…32, and so on.

 

 

Received error in attempting to edit switch

Verify that the data is valid, that the user has

configuration.

permissions to modify the configuration on the

or

switch, that the switch is reachable in the

Received error in attempting to save switch

fabric, and that the fabric is reachable from

configuration.

the user’s workstation, and then retry the

or

configuration change.

Received error in attempting to activate switch

 

configuration.

 

 

 

Reset will complete shortly. There is a brief loss

Wait for the switch to become reachable

of connectivity with switch.

again. This may take up to one minute.

 

 

The new domain ID specified is invalid.

Verify that all information is valid and retry the

Unable to apply invalid chassis/fabric ID

configuration change. Consult the

documentation for valid configurations.

values

Valid domain IDs must be in the range 1 to

 

 

239, and must be unique within a fabric. If the

 

fabric contains Switch with E_Port switches, all

 

domain IDs must be in the same range of

 

sixteen values: 1…16, 17…32, and so on.

 

 

Unable to apply changes. Failed to obtain

Verify that another user is not currently

admin privileges.

modifying the switch configuration, using

 

either the management application, or a telnet

 

login, or any application.

 

 

Unable to apply invalid timeout values.

Verify that all information is valid and retry the

or

configuration change. Consult the

Unable to apply invalid IP address.

documentation for valid configurations.

or

Valid domain IDs must be in the range 1 to

Unable to apply invalid trap address.

239, and must be unique within a fabric. If the

or

fabric contains Switch with E_Port switches, all

Unable to apply invalid subnet mask.

domain IDs must be in the same range of

or

sixteen values: 1…16, 17…32, and so on.

Unable to apply invalid gateway address.

 

or

 

Unable to apply invalid ARP timeout value.

 

 

 

100

HP StorageWorks 2/8q Fibre Channel Switch Management User Guide

Page 100
Image 100
HP 2/8q Fibre Channel manual Domain IDs must be in the same range