Software Fixes in Release M.08.51 - M.10.72
Release M.10.11
Release M.10.11
Problems Resolved in Release M.10.11
■Crash (PR_1000336436) — A “get/put” operation on config file via SCP crashes the box with an error message similar to:
Software exception at ssh_alarm.c:304
■Transceiver (PR_1000349320) — CX4 ports lose configs; "show int config" shows an empty slot rather than CX4.
Release M.10.12
Problems Resolved in Release M.10.12
■Crash (PR_1000351261) — On bootup, the switch with a fixed CX4 card installed will crash with the following message:
Software exception at gamma_xcvr_util.c:1018. Support: this fix is QA only.
■Crash (PR_1000348454) — Crash when a loop is formed on the network, with error message:
NMI event SW:IP=0x002030b4 MSR:0x0000b032 LR:0x002030d4 Task='mMst- pCtrl' Task ID=0x60d6060cr: 0x48000040 sp:0x060d5cc8xer:0x00000000
■Crash (PR_1000350363) — Switch crashes when pinging any other HP switch that is being rebooted, with the following message:
Software exception at cli_oper_action.c:986
■Radius EAP (PR_1000334731) — PEAP/TLS Eap Types with IAS Radius Server fail to authenticate.
Release M.10.13
Problems Resolved in Release M.10.13
■Crash (PR_1000352922) — The switch may crash with a message similar to
Software exception at mstp_ptx_sm.c:118
■Enhancement (PR_1000354065) — DHCP Protection enhancement for switch 3400.
162