Enhancements
Release M.10.04 Enhancements
Configuring Instrumentation Monitor
The following commands and parameters are used to configure the operational thresholds that are monitored on the switch. By default, the instrumentation monitor is disabled.
Syntax: [no] instrumentation monitor [parameterNameall] [<lowmedhighlimitValue>]
[log] : Enables/disables instrumentation monitoring log so that event log messages are generated every time there is an event which exceeds a configured threshold.
(Default threshold setting when instrumentation monitoring is enabled: enabled)
[all] : Enables/disables all counter types on the switch but does not enable/disable instrumentation monitor logging.
(Default threshold setting when enabled: see parameter lisings below)
(Default threshold setting when enabled: 1000 (med))
(Default threshold setting when enabled: 100 (med))
(Default threshold setting when enabled: 10 (med))
(Default threshold setting when enabled: 1000 (med))
(Default threshold setting when enabled: 100 (med))
(Default threshold setting when enabled: 10 (med))
(Default threshold setting when enabled: 50 (med)))
(Default threshold setting when enabled: 3 seconds (med)) [trap] : Enables or disables SNMP trap generation.
(Default setting when instrumentation monitoring is enabled: disabled)
To enable instrumentation monitor using the default parameters and thresholds, enter the general instrumentation monitor command. To adjust specific settings, enter the name of the parameter that you wish to modify, and revise the threshold limits as needed.
73