Software Fixes in Release M.08.51 - M.10.72
Release M.10.28
Release M.10.28
Problems Resolved in Release M.10.28 (Not a general release)
■CLI/LLDP (PR_1000377191) — Output from the CLI command, "show lldp info remote- device <port>" shows a blank field for the chassis ID.
■CLI (PR_1000390970) — The command
■CLI/Counters (PR_1000379222) — Jumbo sized frames received on 10GbE ports decre- ment the "Total Rx Errors" counters. The 32 bit counter rolls from 0 backwards to 4,294,967,295 and continues to decrement with each received Jumbo frame.
■Trunking (PR_1000238829) — Trunks numbered trk10 and greater cause the output from the CLI command "show span" output to be misaligned.
Release M.10.29
Problems Resolved in Release M.10.29 (Never released)
■CLI/Config (PR_1000375830) — When using the "no VLAN" command, the user is asked if they want to remove the VLAN. Answering "no" will result in the VLAN being removed anyway.
■CLI/config (PR_1000391119) — Copying a configuration file to a switch with a BPDU protection timeout value set may produce an error similar to:
CCCCCline: 10007. 1200: Error setting configuration
■CLI (PR_1000390385) — The CLI help text for "span
■Enhancement (PR_1000376626) — Enhance CLI "qos
■Lockup (PR_1000394749) — Switch may lockup when a certain J4858A transceiver type is inserted.
■SNMP (PR_1000392847) — RMON alarms that monitor
■Traceroute (PR_1000379199) — The reported "traceroute" time is inaccurate; it is one decimal place off.
168