Software Fixes in Release M.08.51 - M.10.72

Release M.10.67

CLI (1000415243) — Output from the CLI command show name still lists 10-GbE trans- ceiver names, even after the transceivers are removed and replaced with another type of transceiver.

CLI (PR_1000430534) — Output from the show port-accessmac-based CLI command may omit connected clients.

Enhancement (0000000818) — Enhancement to allow syslog configuration via SNMP. For more information, see “Release M.10.66 Enhancements” on page 140.

Release M.10.67

Problems Resolved in Release M.10.67 (Never Released)

RADIUS Accounting (PR_0000004145) — An incomplete "Calling-Station-ID" field is sent in the accounting-request to the RADIUS server on the boot system command.

RADIUS Accounting (PR_0000004141) — The "Acct-Status-Type" attribute is missing in the accounting-request to RADIUS server on the boot system command.

RADIUS Accounting (PR_0000004139) — Procurve switches do not send the accounting request to RADIUS server on reload command.

TELNET hang (PR_1000457765) — If Ctrl+S is typed and then the Telnet window is closed, the Telnet session may become unresponsive and fail to reset with the kill command issued at the console prompt. This may require the switch to be reloaded to become active again.

GVRP/RADIUS (PR_0000006051) — RADIUS assigned VLANs are not correctly propa- gated in GVRP.

Web-Management (PR_0000002153) — The Web Management interface does not allow configuration of 'static' port-security using a value higher than 8. Selecting 9-32 will change the value to 'limited' in the drop-down box.

MAC Auth/802.1X (PR_0000004095) — When an 802.1X session is closed, the client logout is not seen by the switch. Since the switch does not end the 802.1X session, the client does not succeed at MAC Authentication. This issue has been seen when using an 802.1X client such as the Odyssey Access Client Manager, version 4.60.

802.1X Port Lock-Up (PR_0000005372) — If the first frame is sent from an all zero's MAC address to a broadcast destination address, an 802.1X port will freeze, AAA will quit functioning.

Web-Management (PR_1000451437) — The [?] button in the upper right corner of the Web Management Interface pages brings up an obsolete text message unless there is a “Management Server URL” configured on the switch.

179