Software Fixes in Release M.08.51 - M.10.72

Release M.10.34

Crash (PR_1000407542) — Attempting to change the spanning-tree protocol version from STP to RSTP or MSTP may cause the switch to crash with a message similar to:

PPC Bus Error exception vector 0x300: Stack-frame=0x063d5de0 HW Addr=0x4b5a697c IP=0x0064c648 Task='mSnmpCtrl'

QoS (PR_1000370895) — Once the maximum number of QoS resources is reached, it cannot be cleared without a reboot. The CLI warning message, “Unable to add this QoS rule. Maximum number already reached.” will continue to be displayed until the switch is rebooted.

Enhancement (PR_1000408960) RADIUS-Assigned GVRP VLANs.

DHCP Snooping (PR_1000392148) — Repeatedly toggling DHCP Snooping on and off may crash the switch with a message similar to: Software exception at bcmHwDsnoop.c:

195 -- in 'mAdMgrCtrl', task ID = 0x65a3370 -> BCM ASIC call failed: Table full.

DHCP Snooping (PR_1000403133) DHCP-Snooping stops working after some period of time.

Release M.10.34

Problems Resolved in Release M.10.34

QoS (PR_1000399873) — The QoS priority bits are incorrectly set to priority zero on fragmented frames.

Menu (PR_1000392862) — The menu will allow invalid values (greater than 720 sec) to be entered for the SNTP poll interval.

Crash (PR_1000410959) — If the snmpv3 user is deleted on the switch without deleting the associated parameters, then the switch is rebooted, it will repeatedly crash with a message similar to:

Software exception at exception.c:373 -- in 'mSnmpEvt', task ID = 0x17d1818 -> Memory system error at 0x17c22e0 - memPartFree

Enhancement (PR_1000412747) — TACACS+ Single Sign-on for Administrators

Release M.10.35

Problems Resolved in Release M.10.35

RSTP (PR_1000405368) — When a primary link goes down and then comes back online, traffic continues on the redundant link and does not shift back to the primary link.