HP 480-0005-00-15 manual Diagnostics, Common Symptoms/Problems

Models: 480-0005-00-15

1 185
Download 185 pages 25.91 Kb
Page 143
Image 143

Chapter 8: Diagnostics/Maintenance

Diagnostics

Common Symptoms/Problems

Below is a list of common symptoms and problems you may encounter. Use this list as a guideline; if your problem is not listed, use the diagnostic procedure explained in the beginning of this chapter.

Table 8-1Common Symptoms/Problems

Common Symptom/Problem

Description/Solution

 

 

 

 

Unit will not turn on or LEDs on front lower

For AC units:

swing down panel of the chassis are unlit.

Check AC power source.

 

Check fuse or circuit breaker. To check fuse continuity, see

 

Inspect and Replace Fuse (for AC power only), later in this

 

chapter.

 

Ensure power supplies are fully seated.

 

For DC units:

 

Check that the supplies are fully seated in the DC chassis.

 

Check the customer premises over-current protection

 

device(s) are in the ON position.

 

For Tenor CMS860 and CMS240: Ensure all wires are

 

secured to the power entry plug and the plug is inserted to

 

the power receptacle and secured with the anchor screws.

 

Ensure the circuit breaker for the respective power entry

 

point is switched to the ON position.

 

 

Communication between Tenor CMS and

There are several reasons why communication may not be

the PBX or PSTN cannot be established.

successful. A few of the most common are listed below.

 

Verify correct cables are installed in the rear of the T1/E1/

 

DS1 ports. See Chapter 3: Installation.

 

Unit configuration may be wrong. Examine the configura-

 

tion parameters via CLI.

 

Network issues may cause a number of problems. Contact

 

the Central Office to perform test procedures.

 

 

P/N 480-0005-00-15

8-3

Page 143
Image 143
HP 480-0005-00-15 manual Diagnostics, Common Symptoms/Problems