Chapter 3: Installation

Figure 3-9Strip away wire

DC Power Wire Strip Length

10 - 14 AWG

0.25" (7.0mm)

3.Insert the wire into the connector in the position shown in Figure 3-10.

Figure 3-10Connector position

4.Secure by tightening the clamping screw with a straight blade screwdriver of size 0.023x 0.137 (0.6 x 3.5mm). Screws must be torqued between a minimum of 4.4 lbs in (0.5 Nm) and a maximum of 5.3 lbs in (0.6 Nm).

WARNING: Do not over torque the screws.

5.Repeat steps 2-4 for the RTN and -48V source, respectively, in the same sequence shown in Figure 3-11.

Figure 3-11Wire connection sequence

6.Once the connections are complete between the DC feed(s) and the Tenor CMS power plug (s), insert the plugs into the power receptacles.

7.Secure the power plugs to each of the power receptacles by torquing the screws in the face of the plug to between a minimum of 4.4 lbs in. (0.5Nm) and a maximum of 5.3 lbs in. (0.6Nm) with the same screw- driver. See Figure 3-12.Plug and secure both power plugs, even if only one DC power feed is used.

 

Figure 3-12Plug and secure power plugs

-48 RTN

Secure both screws in the face of the Plug, with a straight

 

blade screwdriver of size 0.023" x 0.137", (0.6 x 3.5mm)

Caution: Screws must be torqued between a minimum of 4.4 lbs.in,(0.5 Nm) and a maximum of 5.3 lbs. in (0.6 Nm)

3-12

P/N 480-0005-00-15

Page 75
Image 75
HP 480-0005-00-15 manual 48 RTN