Chapter 5: Working with SNMP

Working with SNMP

View traps

You can view the traps HP Openview received from the Tenor CMS unit as follows:

NOTE: Ensure HP Openview is running.

1.From the HP Openview map where the Tenor CMS units appear, right-click on the Tenor CMS icon for which you want to view traps and select Alarms.

2.From the Alarm Categories window, click on All Alarms. All traps (alarm messages) will be listed in the order of which they occurred.

View Alarm Status via Tenor CMS icon

Through the color of a Tenor CMS icon on the HP Openview desktop, you can determine the alarm state of the unit as well as view the corresponding alarms. Valid icon colors are listed below.

Green Icon. No Alarm indicated.

Red Icon. Critical Alarm (used for when HP Openview cannot communicate with the Tenor CMS or there is a severity level 1 alarm).

Orange Icon. Major Alarm (used for severity level 2 alarms).

Yellow Icon. Minor Alarm (used for severity level 3 alarms).

White Icon. Info Alarm (used for severity level 4 alarms).

View the alarms associated with a Tenor CMS unit as follows:

NOTE: Ensure HP Openview is running.

1.From the HP Openview desktop, identify the icon for the Tenor CMS unit from which you would like to view alarms.

2.According to the color of that icon, determine the alarm state from the list above.

3.To view the alarms associated with that icon, right-click from anywhere on the HP Openview desktop and select Alarms. The All Alarms Browser window will appear, which contains the list of alarms.

Launching Command Line Interface (CLI) from HP Openview

You can launch the Command Line Interface (CLI) from HP Openview as follows:

Launch Command Line Interface with pop-up menu as follows:

1.From the HP Openview desktop, right-click on the desired Tenor CMS unit icon and select Quintum CMS.

The CLI will launch with the IP address of the unit associated with that icon (the correct IP address will appear in the URL).

5-8

P/N 480-0005-00-15

Page 119
Image 119
HP 480-0005-00-15 manual Working with Snmp, View traps, View Alarm Status via Tenor CMS icon