Post Error Codes and messages (Continued)

 

 

Code

Error Message

 

 

0B33

Power Unit Fan 1 Alarm occurred

 

 

0B34

Power Unit Fan 2 Alarm occurred

 

 

0B46

ESMINT not configured

 

 

0B50

CPU #1 with error taken off line

 

 

0B51

CPU #2 with error taken off line

 

 

0B5F

Forced to use CPU with error

 

 

0B60

DIMM group #1 has been disabled

 

 

0B61

DIMM group #2 has been disabled

 

 

0B62

DIMM group #3 has been disabled

 

 

0B63

DIMM group #4 has been disabled

 

 

0B6F

DIMM group with error is enabled

 

 

0B70

The error occurred during temperature sensor reading

 

 

0B71

System Temperature out of range

 

 

0B74

The error occurred during voltage sensor reading

 

 

0B75

System Voltage out of range

 

 

0B7C

The error occurred during fan sensor reading

0B80

BMC Memory Test Failed

 

 

0B81

BMC Firmware Code Area CRC check failed

 

 

0B82

BMC core hardware failure

 

 

0B83

BMC IBF or OBF check failed

 

 

0B90

BMC Platform Information Area Corrupted

 

 

0B91

BMC update firmware corrupted

 

 

0B92

Internal Use Area of BMC FRU corrupted

 

 

0B93

BMC SDR Repository empty

 

 

0B94

IPMB signal lines do not respond

 

 

0B95

BMC FRU device failure

 

 

0B96

BMC SDR Repository failure

 

 

0B97

BMC SEL device failure

 

 

0BB0

SMBIOS - SROM data read error

 

 

0BB1

SMBIOS - SROM data checksum bad

 

 

0BD0

1st SMBus device address not acknowledged

 

 

0BD1

1st SMBus device Error detected

 

 

0BD2

1st SMBus timeout

 

 

Problem Solving 5-15

Page 117
Image 117
Intel 5800/120Ld manual Post Error Codes and messages