Assembly

This section describes how to assemble your rack-mount server unit into a standard EIA 19-inch rack cabinet.

!CAUTION

Ensure that the location of the rack-mount server unit does not create an unstable condition when installed in the rack cabinet.

Note: Refer to Figure 2-1 while Steps 2 and 3 of this procedure.

1.Select an appropriate location in your rack cabinet for the rack-mount server unit. To improve rack stability, mount heavier items towards the bottom of the rack cabinet.

Note: When planning your system configuration for the rack cabinet you should consider the length of the cables that interconnect system components.

2.Locate the two support brackets (D). Using four self tapping screws (E) supplied with the rack cabinet for each support bracket, attach the two support brackets to the vertical mounting rails (A and B) of the rack cabinet.

3.Install the four caged nuts (C) that secure the front of the rack-mount server unit to the rack cabinet. Position the caged nuts to align with the screw holes in the front bezel of the rack-mount server unit.

Note: The caged nuts are secured into the vertical mounting rails of the rack cabinet by inserting one side of the nut into the slot and squeezing while pressing the opposite side until it snaps into place.

2-4 Setting Up the System

Page 34