Get log all: All the SMC event log data recorded in a server is acquired sequentially from the oldest one and displayed by activating the Windows standard editor WordPad. Since it takes time to make an inquiry to the server, [Connecting] is displayed in the title bar. The operator can do nothing in the dialog box while the message is displayed.
Troubleshooting
This section briefly explains problems and mistakes that may occur during MWA operations.
Problem: The Select a server dialog box does not display server information.
Probable Cause: Server SG information is not registered or the information has been lost. Register the server SG information again.
Problem: MWA cannot be operated after the reset command was executed.
Probable Cause: When some reset commands are issued, MWA waits for a response and cannot perform other operations. Wait for a while.
Problem: The Read button cannot be selected in the Data dialog box.
Probable Cause: Data read from a server is restricted as follows: The server is connected.
CMOS data and DMI data can be read at the end of POST. Stop server processing at the end of POST by selecting the Pause POST command and the Go to End of POST command from the
Problem: A remote drive cannot be used.
Probable Cause: See Using a Remote Drive.
Problem: Booting from a remote drive failed.
Probable Cause: Check the following: The remote drive is set correctly.
The remote drive is a floppy disk (or a FD image file) from which MS- DOS can be booted.
The priority of the boot device of the server is a floppy disk.