Intel BX80646I74770S Thermal Metrology, Fan Speed Control Scheme with Digital Thermal Sensor DTS

Models: BX80633I74960X BX80646I34130 BX80646I54430 BX80646I74770K BX80646I74770 BX80646I54570S BX80646I74770S BXF80646I74770K CM8063701159502 CM8063701212200 BX80637I73770K CM8064601466003 CM8064601466200

1 120
Download 120 pages 30.96 Kb
Page 71
Image 71
5.2Thermal Metrology

Thermal Management—Processor

5.2Thermal Metrology

The maximum Thermal Test Vehicle (TTV) case temperatures (TCASE-MAX) can be derived from the data in the appropriate TTV thermal profile earlier in this chapter. The TTV TCASE is measured at the geometric top center of the TTV integrated heat spreader (IHS). The following figure illustrates the location where TCASE temperature measurements should be made.

Figure 19. Thermal Test Vehicle (TTV) Case Temperature (TCASE) Measurement Location

Measure TCASE at

the geometric center of the package

37.5

37.5

Note: THERM-X OF CALIFORNIA can machine the groove and attach a thermocouple to the IHS. The supplier is subject to change without notice. THERM-X OF CALIFORNIA, 1837 Whipple Road, Hayward, Ca 94544. Ernesto B Valencia +1-510-441-7566 Ext. 242 ernestov@therm-x.com. The vendor part number is XTMS1565.

5.3Fan Speed Control Scheme with Digital Thermal Sensor (DTS) 1.1

To correctly use DTS 1.1, the designer must first select a worst case scenario TAMBIENT, and ensure that the Fan Speed Control (FSC) can provide a ΨCA that is equivalent or greater than the ΨCA specification.

The DTS 1.1 implementation consists of two points: a ΨCA at TCONTROL and a ΨCA at DTS = -1.

Desktop 4th Generation Intel® CoreProcessor Family, Desktop Intel® Pentium® Processor Family, and Desktop Intel® Celeron® Processor Family

December 2013

Datasheet – Volume 1 of 2

Order No.: 328897-004

71

Page 71
Image 71
Intel BX80646I74770S, BX80646I54430 Thermal Metrology, Fan Speed Control Scheme with Digital Thermal Sensor DTS, 37.5 37.5