Page 25
Image 25

 

The server can boot and run the operating system, but mouse and

 

keyboard input is not accepted until the user password is entered.

 

At boot time, if a CD is detected in the CD-ROM drive or a diskette in drive

 

A, the system prompts for a password. When the password is entered, the

 

server boots from CD or diskette and disables the secure mode.

 

If there is no CD in the CD-ROM drive or diskette in drive A, the server

 

boots from drive C and automatically goes into secure mode. All enabled

 

secure mode features go into effect at boot time.

 

To leave secure mode: Enter the correct password(s).

Disable writing

In secure mode, the server will not boot from or write to a diskette unless a

to diskette

password is entered.

 

To write protect access to diskette whether the server is in secure mode or

 

not, use the Setup main menu, Floppy Options, and specify Floppy Access

 

as read only.

Set a time out

Specify and enable an inactivity time out period of from 1 to 120 minutes.

period so that

If no keyboard or mouse action occurs for the specified period, attempted

keyboard and

mouse input

keyboard and mouse input will not be accepted.

are not

The monitor display will go blank, and the diskette drive will be write

accepted

Also, screen

protected (if these security features are enabled through Setup).

To resume activity: Enter the correct password(s).

can be

blanked, and

 

writes to

 

diskette can

 

be inhibited

 

Control access

To control access to setting or changing the system configuration, set a

to using the

supervisor password and enable it through Setup.

SSU: set

 

supervisor

If both the supervisor and user passwords are enabled, either can be used

password

to boot the server or enable the keyboard and/or mouse, but only the

 

supervisor password will allow Setup to be changed.

 

To disable a password, change it to a blank entry or press CTRL-D in the

 

Change

 

Password menu of the Supervisor Password Option menu found in the

 

Security

 

Subsystem Group.

 

To clear the password if you cannot access Setup, change the Clear

 

Password jumper (see Chapter 9).

Control access

To control access to using the system, set a user password and enable it

to the system

through

other than

Setup.

SSU: set user

 

password

To disable a password, change it to a blank entry or press CTRL-D in the

 

Change