Server Menu
Table 22: Server Menu Features
Feature | Choices | Description |
System Management | Press <Enter> | Enters Submenu. |
Console Redirection | Press <Enter> | Enters Submenu. |
Event Log Redirection | Press <Enter> | Enters Submenu |
Service Boot | Enable | If enabled, server boots directly to System |
| Disable | Management. |
Assert NMI on PERR | Disabled | If enabled, PCI bus parity error (PERR) routes to NMI. |
| Enabled |
|
Assert NMI on SERR | Disabled | If enabled, PCI bus system error (SERR) routes to |
| Enabled | NMI. |
Disable BSP | Controls the policy of the | |
| Do not Disable | determines when the Boot Strap Processor (BSP) |
| BSP | should be disabled if an |
| Retry 3 Times |
|
BMC IRQ | Disabled | Sets the BMC IRQ. |
| IRQ 5 |
|
| IRQ 11 |
|
After Power Failure | Stays Off | Determines the mode of operation if a power loss |
| Last State | occurs. |
| Power On |
|
Temperature Sensor | Disabled | If enabled, the system will not boot if the ambient |
| Enabled | system temperature is outside the range specified in |
|
| the Sensor Data Record (SDR). |
|
|
|
POST Error Pause | Disabled | If enabled, the system will wait for user intervention on |
| Enabled | critical POST errors. |
|
|
|
Platform Event Filtering | Disabled | Enable/Disable triggers for system sensor events |
| Enabled | inside the Baseboard Management Controller (BMC). |
Server Redirection Submenu
Table 23: Server Redirection Submenu Features
Feature | Choices | Description |
|
|
|
Board Part Number | N/A | Information field only |
|
|
|
Board Serial Number | N/A | Information field only |
|
|
|
System Part Number | N/A | Information field only |
|
|
|
System Serial Number | N/A | Information field only |
|
|
|
Chassis Part Number | N/A | Information field only |
|
|
|
Chassis Serial Number | N/A | Information field only |
|
|
|
BIOS Revision BMC | N/A | Information field only |
|
|
|
Revision Primary HSBP | N/A | Information field only |
|
|
|
Revision | N/A | Information field only |
|
|
|
Console Redirection Submenu
Table 24: Console Redirection Submenu Features
Feature | Choices | Description |
|
|
|
Serial Console Redirection | Disabled | If enabled, BIOS uses the specified serial port to |
| Enabled | redirect the console to a remote ANSI terminal. |
|
| |
|
| Enabling this option will disable the Quiet Boot option. |
|
|
|
Serial Port | COM1 3F8 IRQ4 | Serial port and IRQ designated for server |
|
|
|
Viglen SX220 User Guide | 65 |