Server Menu

Table 22: Server Menu Features

Feature

Choices

Description

System Management

Press <Enter>

Enters Submenu.

Console Redirection

Press <Enter>

Enters Submenu.

Event Log Redirection

Press <Enter>

Enters Submenu

Service Boot

Enable

If enabled, server boots directly to System

 

Disable

Management.

Assert NMI on PERR

Disabled

If enabled, PCI bus parity error (PERR) routes to NMI.

 

Enabled

 

Assert NMI on SERR

Disabled

If enabled, PCI bus system error (SERR) routes to

 

Enabled

NMI.

FRB-2 Policy

Disable BSP

Controls the policy of the FRB-2 timeout. This option

 

Do not Disable

determines when the Boot Strap Processor (BSP)

 

BSP

should be disabled if an FRB-2 error occurs.

 

Retry 3 Times

 

BMC IRQ

Disabled

Sets the BMC IRQ.

 

IRQ 5

 

 

IRQ 11

 

After Power Failure

Stays Off

Determines the mode of operation if a power loss

 

Last State

occurs.

 

Power On

 

Temperature Sensor

Disabled

If enabled, the system will not boot if the ambient

 

Enabled

system temperature is outside the range specified in

 

 

the Sensor Data Record (SDR).

 

 

 

POST Error Pause

Disabled

If enabled, the system will wait for user intervention on

 

Enabled

critical POST errors.

 

 

 

Platform Event Filtering

Disabled

Enable/Disable triggers for system sensor events

 

Enabled

inside the Baseboard Management Controller (BMC).

Server Redirection Submenu

Table 23: Server Redirection Submenu Features

Feature

Choices

Description

 

 

 

Board Part Number

N/A

Information field only

 

 

 

Board Serial Number

N/A

Information field only

 

 

 

System Part Number

N/A

Information field only

 

 

 

System Serial Number

N/A

Information field only

 

 

 

Chassis Part Number

N/A

Information field only

 

 

 

Chassis Serial Number

N/A

Information field only

 

 

 

BIOS Revision BMC

N/A

Information field only

 

 

 

Revision Primary HSBP

N/A

Information field only

 

 

 

Revision

N/A

Information field only

 

 

 

Console Redirection Submenu

Table 24: Console Redirection Submenu Features

Feature

Choices

Description

 

 

 

Serial Console Redirection

Disabled

If enabled, BIOS uses the specified serial port to

 

Enabled

redirect the console to a remote ANSI terminal.

 

 

 

 

Enabling this option will disable the Quiet Boot option.

 

 

 

Serial Port

COM1 3F8 IRQ4

Serial port and IRQ designated for server

 

 

 

Viglen SX220 User Guide

65

Page 66
Image 66
Intel SX220 manual Server Menu, Server Redirection Submenu, Console Redirection Submenu