Current Usage
NOTE: Both processors pull power from +5V. This may limit the number of drives and/or
As an overall current usage limitation on the power supply, do not exceed a combined power output of 195 watts for the +5 and +3.3 volt outputs.
The PCI slots on the server board are rated at a maximum of 5 amperes per slot. The maximum power allowed for each slot is 20 watts at +5 volts. The average current usage per slot should not exceed 3.0 amperes per slot; that is, 15 watts.
The cooling efficiency varies per slot; therefore, ensure that adequate cooling is available in the target
Calculating Power Consumption
The total combined wattage for the system configuration must be less than the output of your power supply. Use the two worksheets in this section to calculate the power used by your server boards. For current and voltage requirements of