JUNOS Software with Enhanced Services Hardware Guide

off and on again, we recommend waiting a few seconds between shutting it down and powering it back up. Table 13 on page 28 describes the STATUS LED.

Table 13: STATUS LED

Color

State

Description

Green

Blinking

Router is starting up or performing diagnostics.

 

On steadily

Router is operating normally.

Red

Blinking

Error has been detected.

ALARM LED

The ALARM LED lights yellow to indicate a minor condition that requires monitoring or maintenance and lights red to indicate a major condition that can result in a system shutdown. When the condition is corrected, the light turns off. Table 14 on page 28 describes the ALARM LED.

Table 14: ALARM LED

Color

State

Description

Red

On steadily

Major alarm indicates a critical situation on the router that

 

 

has resulted from one of the following conditions. A red

 

 

alarm condition requires immediate action:

 

 

One or more hardware components have failed.

 

 

One or more hardware components have exceeded

 

 

temperature thresholds.

 

 

An alarm condition configured on an interface has

 

 

triggered a critical warning.

Yellow

On steadily

Minor alarm condition requires monitoring or maintenance:

 

 

Indicates a noncritical condition on the router that, if

 

 

left unchecked, might cause an interruption in service

 

 

or degradation in performance.

 

 

A missing rescue configuration or software license

 

 

generates a yellow system alarm.

Unlit

Off

No alarms.

For information about alarm conditions and corrective actions, see “Monitoring and Correcting Chassis Alarm Conditions” on page 157. For additional information, see the JUNOS Software Administration Guide.

28J4350 and J6350 Services Router Hardware Features

Page 52
Image 52
Juniper Networks J2350 manual Status LED, Alarm LED, 28 J4350 and J6350 Services Router Hardware Features