Chapter 4: Preparing for Router Installation

CAUTION: To comply with intrabuilding lightning/surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends.

Router Power Requirements

Table 35 on page 69 and Table 36 on page 69 list the AC and DC power system electrical specifications for Services Routers.

Table 35: AC and DC Power System Electrical Specifications for J2320 and J2350 Routers

Item

Specification

AC input voltage

100 to 240 VAC nominal

AC input line frequency

50 to 60 Hz

AC system current rating

J2320 Services Routers: 3.2 A to 1.3 A

 

J2350 Services Routers: 3.5 A to 1.5 A

DC input voltage

–48 to –60 VDC operating range

DC system current rating

7.2 A

Table 36: AC and DC Power System Electrical Specifications for J4350 and J6350 Routers

Item

Specification

AC input voltage

100 to 240 VAC nominal

AC input line frequency

50 to 60 Hz

AC system current rating

J4350 Services Routers: 6 A

 

J6350 Services Routers: 8 A

DC input voltage

–48 to –60 VDC operating range

DC system current rating

20 A

AC Power, Connection, and Power Cord Specifications

NOTE: The AC power cord for the Services Router is intended for use with the router only and not for any other use.

Power Guidelines, Requirements, and Specifications 69

Page 93
Image 93
Juniper Networks J2350 manual Router Power Requirements, AC Power, Connection, and Power Cord Specifications