Chapter 8: Replacing Hardware Components

Replacing Air Filters on J2350 Routers

The cooling fans on J2350 routers draw air through vents along the left side of the chassis and exhaust it through vents on the right side of the chassis. For more information, see “J2320 and J2350 Cooling System” on page 19.

On J2350 routers that comply with Network Equipment Building System (NEBS) criteria, the air intake grid contains a filter. To verify that the system is a NEBS-compliant system, run the show chassis hardware command. A NEBS-compliant system displays the term NEBS in the output.

We recommend changing the filter every 6 months. However, the optimal filter replacement interval can vary depending on the environment where the router is located. If temperature alarms appear, inspect the air filter.

To replace the air filter:

1.Loosen the filter tray thumbscrew at the rear of the J2350 chassis.

2.Hold the screw firmly and pull it away from the chassis until you have pulled the attached filter tray out of the chassis (see Figure 87 on page 153).

Figure 87: Removing the Air Filter Tray

3.Hook-and-loop fasteners on the base of the filter tray hold the air filter inside the tray. Grasp the air filter with your fingers and gently pull it away from the filter tray.

4.Set the old air filter aside.

5.Place the new filter so that its edge aligns with the first hook-and-loop fastener as shown Figure 88 on page 154.

Replacing Air Filters on J2350 Routers 153

Page 177
Image 177
Juniper Networks manual Replacing Air Filters on J2350 Routers