JUNOS Software with Enhanced Services Hardware Guide

Figure 33: E3 PIM

The T3 and E3 PIMs provide the following key features:

Onboard network processor

Integrated DSU—Eliminates the need for a separate external device

Subrate and scrambling options with support for major DSU vendors

Independent internal and external clocking system

Loopback (payload–supported only on T3 PIM, local, and remote), bit error rate test (BERT), and T3 far-end alarm and control (FEAC) diagnostics

For pinouts of cable connectors for T3 and E3 PIMs, see “E3 and T3 BNC Connector Pinout” on page 194.

To install or remove a PIM, see “Replacing a PIM” on page 120.

Status LEDs indicate port status. Table 28 on page 52 describes the meaning of the LED states.

Table 28: Status LEDs for T3 and E3 Ports

Color

State

Description

Green

On steadily

Online with no alarms or failures.

Red

On steadily

Active with a local alarm. The router has

 

 

detected a failure.

Yellow

On steadily

Loopback mode.

 

 

T3 (DS3)—Remote endpoint is in red

 

 

alarm failure.

 

 

E3—Remote defect indication (RDI).

Unlit

Off

Offline.

For alarms, see the configuring and monitoring alarms information in the JUNOS

Software Administration Guide.

52Field-Replaceable PIMs

Page 76
Image 76
Juniper Networks J2350 manual E3 PIM, Status LEDs for T3 and E3 Ports