4. Maintenance Mode

4-1. Function of Maintenance Mode

This device has the maintenance mode that executes maintenance functions.

Touching [MAINTENANCE] on the control panel on OFF LINE will switch into the maintenance mode and display the maintenance screen on the control panel.

In addition to the maintenance operations, the START TIMER function can be set, and re-printing of the data that has already been printed can be made, etc.

The print data from the diagnostic device cannot be received or printing cannot be made in the mainte- nance mode.

The following shows the maintenance items that can be selected/executed in the maintenance mode.

No.

Display

 

 

Description

 

 

 

 

 

1

START TIMER

Sets the START TIMER function to ON/OFF, and sets the start-up time for

 

 

each day.

 

 

 

The START TIMER screen will appear. (Refer to page 18.)

 

 

 

 

 

2

TIME SET

Sets the time of the clock of the device. The TIME SET screen will appear.

 

 

(Refer to page 19.)

 

 

 

 

 

3

PREVIOUS PRINT

Re-prints the saved data that has been already printed out (PREVIOUS data).

 

 

The PREVIOUS PRINT screen will appear. (Refer to page 20.)

 

 

 

 

 

4

CALIBRATION

Prints the calibration sheet and corrects the density on the film. (Refer to

 

 

page 24.)

 

 

 

 

 

 

5

TEST PRINT

Prints out the SMPTE pattern to control the density.

 

 

The TEST PRINT screen will appear. (Refer to page 26.)

 

 

 

 

 

6

COVER OPEN

Open the front cover. (Refer to page 30.)

 

 

 

 

 

7

PANEL ADJUST

Adjusts the LCD contrast, the brightness of the backlight, and the touch area

 

 

in the touch panel.

 

 

The PANEL ADJUST screen will appear. (Refer to page 31.)

 

 

 

 

 

8

QUEUE CLEAR

Clears the data queued in the device that has not been printed yet.

 

 

The QUEUE CLEAR screen will appear. (Refer to page 33.)

 

 

 

 

 

9

COLD START

Cold-starts (re-start) the device. (Refer to page 35.)

 

 

 

CAUTION

When the device is re-started by COLD START, all

 

 

 

 

of the print data queued for printing and the saved

 

 

 

 

 

 

 

 

data that has been already printed out will be

 

 

 

 

deleted.

 

 

 

 

 

10

FILM DATA

Confirms the sum of film. Sets the types of film to be counted, and date on

 

 

which film is counted. (Refer to page 36.)

 

 

 

 

 

11

PRINT CONDITION

Sets the print preferences for each of the connected diagnostic devices.

 

 

(Refer to page 38.)

 

 

 

 

 

12

USER LUT

Creates user's own LUT curve, and applies it to the diagnostic device. (Refer

 

 

to page 43.)

 

 

 

 

 

 

13

FILMSET RETRY

Used when the film fails to be loaded. (Refer to page 61.)

 

 

 

 

 

 

 

 

CAUTION

Do not use this mode under the normal operation

 

 

 

 

as the number of films in the tray resets to 0.

 

 

 

 

 

 

 

 

 

14

POWER SAVE

Sets the power saving function of the device. (Refer to page 45.)

 

 

 

 

 

CAUTION

The print data from the diagnostic device cannot be received or printing cannot be made in the maintenance mode. The print data queued for printing will be printed out after the device exits from the maintenance mode.

16 DRYPRO MODEL 752 Operation Manual Ver.0.11 2002.6

Page 28
Image 28
Konica Minolta 752 operation manual Function of Maintenance Mode