"Calibrating Density (CALIBRATION)
The device has the densitometer in the cooling/discharge section, which allows you to control the density automatically.
If there is a problem with the density, print the calibration sheet from this screen to calibrate the density.
•Calibration
(1)Touch [CALIBRATION] on the maintenance menu screen.
The message for selecting the tray will appear.
(2)Touch the key of the tray for which you wish to per- form density correction.
The print data in the calibration sheet will be queued, and the maintenance menu screen will
If you wish to perform density correction for the other tray, repeat from Step (1).
(3)Touch [EXIT] to end the maintenance mode.
When the normal screen
IMPORTANT
•The calibration sheet is used as the sampling data (the data before the density correction) for the automatic density correction.
When you check and control the density, use the SMPTE pattern which is printed out by TEST PRINT on the maintenance menu. (Refer to page 26.)