6 Line, Tunnel, Terminal, and Host Settings

Tunnel -

Description

Accept Mode

 

Page Settings

 

 

 

 

Modem Control Asserted = start waiting for an incoming

 

connection as long as the Modem Control pin (DSR) is

 

asserted on the serial line until a connection is made.

 

Modem Emulation = start waiting for an incoming connection

 

when triggered by modem emulation AT commands. Connect

 

mode must also be set to Modem Emulation.

 

 

Local Port

Enter the port number for use as the local port. The defaults

 

are port 10001 for Tunnel 1 and port 10002 for Tunnel 2.

 

 

Protocol

Select the protocol type for use with Accept Mode. The default

 

protocol is TCP. If you select TCP AES you will need to

 

configure the AES keys.

 

 

TCP Keep

Enter the time, in seconds, the XPort Pro waits during a silent

Alive

connection before checking if the currently connected network

 

device is still on the network. If the unit then gets no response

 

after 8 attempts, it drops that connection.

 

 

Flush Serial

Select Enabled to flush the serial data buffer on a new

Data

connection.

 

 

Block Serial

Select On to block, or not tunnel, serial data transmitted to the

Data

XPort Pro.

 

 

Block Network

Select On to block, or not tunnel, network data transmitted to

Data

the XPort Pro.

 

 

Password

Enter a password that clients must send to the XPort Pro

 

within 30 seconds from opening a network connection to

 

enable data transmission.

 

The password can have up to 31 characters and must contain

 

only alphanumeric characters and punctuation. When set, the

 

password sent to the XPort Pro must be terminated with one of

 

the following: (a) 0x0A (LF), (b) 0x00, (c) 0x0D 0x0A (CR LF),

 

or (d) 0x0D 0x00.

 

 

Email on

Select whether the XPort Pro sends an email when a

Connect

connection is made. Select None if you do not want to send an

 

email. Otherwise, select the Email profile to use for sending.

 

 

Email on

Select whether the XPort Pro sends an email when a

Disconnect

connection is closed. Select None if you do not want to send

 

an email. Otherwise, select the Email profile to use for

 

sending.

 

 

CP Output

Identifies a CP or CP Group whose value should change when

 

a connection is established and dropped.

 

 

3.Click Submit.

XPort Pro™ User Guide

43

Page 43
Image 43
Lantronix 900-560 manual Local Port, TCP Keep, Alive, Flush Serial, Data, Block Serial, Block Network, Password, Email on