DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Install Emergency Transfer Unit and Associated Telephones

Page 1-93

 

 

Table 1-17. Pin Assignments for 25-Pair Connector on 808A — Continued

 

Pin

Color

Designation

Connector/Description

 

 

 

 

 

 

15

S-BK

RLC4

Ring-PBX Line Port 4

 

 

 

 

 

 

41

Y-BL

TST4

Tip-Emergency Terminal 4

 

 

 

 

 

 

16

BL-Y

RST4

Ring-Emergency Terminal 4

 

 

 

 

 

 

42

Y-O

TTC5

Tip-PBX Trunk Circuit 5

 

 

 

 

 

 

17

O-Y

RTC5

Ring-PBX Trunk Circuit 5

 

 

 

 

 

 

43

Y-G

TTK5

Tip-CO Trunk Circuit 5

 

 

 

 

 

 

18

G-Y

RTK5

Ring-CO Trunk Circuit 5

 

 

 

 

 

 

44

Y-BR

TLC5

Tip-PBX Line Port 5

 

 

 

 

 

 

19

BR-Y

RLC5

Ring-PBX Line Port 5

 

 

 

 

 

 

45

Y-S

TST5

Tip-Emergency Terminal 5

 

 

 

 

 

 

20

S-Y

RST5

Ring-Emergency Terminal 5

 

 

 

 

 

 

46

V-BL

COM1

Common 1 Relay Contact

 

 

 

 

 

 

21

BL-V

NO1

Normally Open 1 Contact

 

 

 

 

 

 

47

V-O

NC2

Normally Closed 2 Contact

 

 

 

 

 

 

22

O-V

NC1

Normally Closed 1 Contact

 

 

 

 

 

 

48

V-G

COM2

Common 2 Relay Contact

 

 

 

 

 

 

23

G-V

NO2

Normally Open 2 Contact

 

 

 

 

 

 

49

V-BR

 

 

 

 

 

 

 

 

 

24

BR-V

 

 

 

 

 

 

 

 

 

50

V-S

GRD

Ground From PBX

 

 

 

 

 

 

25

S-V

-48PX

-48V from Alarm Panel (AUX Cable)

 

 

 

 

 

 

 

 

 

 

 

 

Continued on next page

9.Check the system for emergency transfer operation as follows:

a. Place the test switch (switch 12) in the ACTIVATED position. b. The power LED should be OFF.

c. Verify there is dial tone on all emergency transfer sets.

Page 101
Image 101
Lucent Technologies 555-230-128 manual RLC4