DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Install and Wire Telephones and Other Equipment

Page 1-59

 

 

Analog Tie Trunk Example

T1

26

29

T2

R1

1

4

R2

T11

27

 

 

30

T12

 

 

R11

2

5

R12

E1 28

31

E2

M1

3

6

M2

 

 

tie_wire RBP 040596

Figure Notes

1. External trunk or adapter

2. Tie trunk circuit pack

Figure 1-28. Analog Tie Trunk Wiring

1.Before installing the Tie Trunk circuit pack, set the option switches as

described in Chapter 2, ‘InstallationCompletion and Cable Pinouts’.

2.Install cross-connect jumpers to connect the pins from the Tie Trunk circuit pack to the appropriate leads on the external tie trunk. Names of the tie trunk leads must be determined from the manufacturer or supplier of the external trunk circuit. The example in Figure 1-28 shows a DEFINITY System tie trunk connected to a DEFINITY System tie trunk.

3.Administer on the Trunk Group Screen. See DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.

Page 67
Image 67
Lucent Technologies 555-230-128 manual Analog Tie Trunk Example, External trunk or adapter Tie trunk circuit pack