DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

 

 

2Installation Completion and Cable Pinouts

Set Neon Voltage — Ring Ping

Page 2-3

Set Neon Voltage Ring Ping

NOTE:

If the ringing option is set to 50 Hz, neon voltage is not available. If 25 Hz is selected, the maximum voltage is 120 volts. Refer to ‘SetRinging Option’’ on page 1-45.

NOTE:

Set the control to OFF if there are no neon message waiting lamps or if LED message lamps are used. See Figure 2-1.

didmt1 KLC 053097

Figure 2-1. Setting the Neon Voltage

1.Call a telephone with a neon message indicator and leave a message.

2.Check for “ring ping” (single ring pulse) each time the lamp flashes (approximately every 3 seconds).

3.Adjust the control clockwise in small increments until the ring ping stops. Be sure that the message lamp still lights when the adjustment is finished.