DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

 

 

2Installation Completion and Cable Pinouts

Set Neon Voltage — Ring Ping

Page 2-3

Set Neon Voltage Ring Ping

NOTE:

If the ringing option is set to 50 Hz, neon voltage is not available. If 25 Hz is selected, the maximum voltage is 120 volts. Refer to ‘SetRinging Option’’ on page 1-45.

NOTE:

Set the control to OFF if there are no neon message waiting lamps or if LED message lamps are used. See Figure 2-1.

didmt1 KLC 053097

Figure 2-1. Setting the Neon Voltage

1.Call a telephone with a neon message indicator and leave a message.

2.Check for “ring ping” (single ring pulse) each time the lamp flashes (approximately every 3 seconds).

3.Adjust the control clockwise in small increments until the ring ping stops. Be sure that the message lamp still lights when the adjustment is finished.

Page 111
Image 111
Lucent Technologies 555-230-128 manual Set Neon Voltage Ring Ping, Setting the Neon Voltage