DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Install and Set Up the Management Terminal

Page 1-42

 

 

Install and Set Up the Management

Terminal

To prevent unnecessary trouble tickets, do not enable the system alarms (Alarm Origination feature) before completing all installation and administration procedures.

1.Remove and retain the installation and usage instructions from the carton. These instructions are needed to set up the terminal after installation. See Figure 1-22.

2.Locate the management terminal within 50 feet (15.2 m) of the system. It may be necessary to reduce the maximum distance limitation if higher gauge wire is used or if the capacitive load on the line is increased.

3.Connect the supplied 25-pin DTE management terminal cable (H600-426) into the TERM connector (J3) on the Processor Interface Cable. See Table 2-7 on page 2-11 for the pinout.

4.Connect an optional printer to either the management terminal (using the supplied adapter cable) or to the DCE connector (J2) on the Processor Interface Cable. See Table 2-7 on page 2-11 for the pinout of the DCE connector.

5.Set the terminal power switch to the ON position when finished.

Page 50
Image 50
Lucent Technologies 555-230-128 manual Install and Set Up the Management Terminal