1 Install and Cable the Cabinets

 

Connect Modem to Telephone Network

Page 1-99

 

 

8.For non-United States installations, set the remaining modem fields as shown in Table 1-20.

9.Press Enter when the modem fields are properly administered.

Table 1-20. Release 6 CMC Modem Fields

 

Field

Description

 

 

 

 

 

Modem

Default is none for Release 6 CMC. Set to external if a modem is used.

 

Connection

 

 

 

 

 

 

 

Modem Name

This field is 20 characters long and permits alphanumeric characters to

 

 

provide a unique qualifier for a given modem.

 

 

 

 

 

RTS/CTS

Informs modem that communication with the data source UART is driven

 

Enabled

with RTS/CTS flow control. The default 6-character field name is &H1.

 

 

Set the field name to \Q3 for Intel modems. This field is not

 

 

case-sensitive.

 

 

 

 

 

Asynchronous

Configures modem as an asynchronous device. This 8-character field

 

Data Mode

name has a default value of &M0 (default) for Release 6csi. Set the field

 

 

to &M0&Q0 for Intel modems. This field is not case-sensitive.

 

 

 

 

 

DTE

Adjusts the speed of the data source (DTE) UART to the outgoing

 

Auto-Data

(modem-to-modem) data rate. At maximum, this speed is 9600 baud. It

 

Speed

is not desirable to have the serial data fill the modem buffer faster than

 

 

the outgoing data rate, since data compression is disabled. The field

 

 

name has a 6-character blank default value. The Paradyne products use

 

 

S90=1 to enable this functionality while the Intel product uses \J1 to

 

 

enable similar functionality. This field is not case-sensitive.

 

 

 

 

 

Disable Data

Turns off the default data compression algorithms used by most

 

Compression

modems. The field has a blank field of 6 characters as default. The AT

 

 

commands that control this are supported by similar commands;

 

 

however, these commands do not operate in the same manner. The Intel

 

 

modems require H0%C0 to disable V.42bis & MNP Class 5 data

 

 

compression algorithms. The Paradyne products only use %C0 to

 

 

disable both algorithms. This field is not case-sensitive.

 

 

 

 

 

Enable Error

Turns on the V.42 LAPM and MNP error control protocols. The field has a

 

Control

blank default of 6 characters. The Paradyne products use the command

 

 

\N5 to enable V.42/MNP/Buffer error control while the Intel product uses

 

 

\N3 to provide similar functionality.

 

 

 

 

 

Misc. Init.

This field has a 20-character blank default and supports any initialization

 

Param

parameters not already specified. The AT commands specified in this

 

 

field are always the last initialization parameters to be sent to the

 

 

external modem. This field is not case-sensitive.

 

 

 

 