DEFINITY Enterprise Communications Server Release 6 | Issue 3 |
Installation and Test for Compact Modular Cabinets | May 1998 |
1 Install and Cable the Cabinets |
|
Activate and Administer the System | Page |
|
|
Log into the System
1.Verify the screen displays: Login:
2.Type craft and press Enter.
3.Type crftpw and press Enter. The password does not display as it is typed. The screen displays the system software version and the terminal types.
Terminal Type (513, 715, 4410, 4425, VT220): [513]
4.Enter the type of management terminal (such as 715) and press Enter.
Check System Status
The system status may suggest problem areas. Refer to DEFINITY Enterprise
Communications Server Release 6 Maintenance for R6csi.
1.Type status system
2.Verify the screen displays a service state of in for all appropriate areas.
Change Customer Options
Refer to DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description to view a sample screen.
The following features are part of the basic software package and do not require activation. They default to y (yes) on the Optional Features form.
■ARS/AAR Partitioning
■Emergency Access to Attendant
■Hospitality (Basic)
■Service Observing
NOTE:
An init login is required to change customer options. Contact your regional
CSA (Customer Software Administrator) to perform this function.
1.Enter change
2.Using the customer order, enable the optional features purchased by the customer (as shown by PEC codes on the customer order).
3.Press Enter when finished to submit the form.
4.Logoff and then log back in to affect the customer option changes.