DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Activate and Administer the System

Page 1-47

 

 

Log into the System

1.Verify the screen displays: Login:

2.Type craft and press Enter.

3.Type crftpw and press Enter. The password does not display as it is typed. The screen displays the system software version and the terminal types.

Terminal Type (513, 715, 4410, 4425, VT220): [513]

4.Enter the type of management terminal (such as 715) and press Enter.

Check System Status

The system status may suggest problem areas. Refer to DEFINITY Enterprise

Communications Server Release 6 Maintenance for R6csi.

1.Type status system all-cabinets and press Enter.

2.Verify the screen displays a service state of in for all appropriate areas.

Change Customer Options

Refer to DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description to view a sample screen.

The following features are part of the basic software package and do not require activation. They default to y (yes) on the Optional Features form.

ARS/AAR Partitioning

Emergency Access to Attendant

Hospitality (Basic)

Service Observing

NOTE:

An init login is required to change customer options. Contact your regional

CSA (Customer Software Administrator) to perform this function.

1.Enter change system-parameters customer-options and press Enter.

2.Using the customer order, enable the optional features purchased by the customer (as shown by PEC codes on the customer order).

3.Press Enter when finished to submit the form.

4.Logoff and then log back in to affect the customer option changes.

Page 55