1 Install and Cable the Cabinets

 

Install the BRI Terminating Resistor

Page 1-80

 

 

Figure 1-35 shows the wiring connections for the 110RA1-12 terminal block. The TN556 BRI switch port is terminated to bottom row C.

1

9

10

11

6

2

T R T1 R1

6

7

3

8

4

term_blk RPY 012098

5

Figure Notes

 

 

1.

Part of terminating resistor block

7.

Basic multi-point option

2.

White or purple field

8.

4-pair horizontal cables

3.

Part of 4-pair blue field

9.

Row “A”

4.

From ISDN T-interface circuit

10.

Row “B”

 

(2-pair)

11.

Row “C”

 

 

5.To ISDN S/T-interface terminals

6.2-pair cross-connect

Figure 1-35. Typical Installation of Terminating Resistor Block

For point-to-point wiring, the top row connects to the blue station field. The pair connects from the 110RA1-12 to the standard 4-pair circuit. Pair 1 from the 110RA1-12 is connected to Pair 1 of the station field, and Pair 2 is connected to Pair 3 of the station field.

Two terminal basic multi-point applications are accommodated by connecting row B (output) to the second terminal common to the multi-point circuit.