DEFINITY Enterprise Communications Server Release 6 | Issue 3 |
Installation and Test for Compact Modular Cabinets | May 1998 |
1 Install and Cable the Cabinets |
|
Install | Page |
|
|
Figure 1-40 shows the connections for up to 24 off-premises analog telephones. Concentrations of analog line pairs are used at both buildings to minimize the off-premises wiring required. At the MDF, jumpers must be connected between 1 row/connecting block in the white field and up to 3 rows/connecting blocks in the purple field. At the station location, a WP-90929, List 1 Concentrator Cable is used. There are 8 station appearances on each of the 3 fingers of the concentrator cable.
1
6
22
5
7
7
45
3
8
9 10
5
11 |
| 12 |
|
7
7
7
7
crdf24o RPY 012398
Figure Notes
1.Locally engineered cables
2.
3.B25A cable
4.Concentrator cable (WP90929 List 1)
5.356A adapter
6.
7.
8.Part of MDF
9.Station side (white field)
10.System side (purple field)
11.
12.To TN2183, TN769, TN742, or TN746B analog line circuit pack