DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

 

 

1Install and Cable the Cabinets

CAMA/E911 Installation

Page 1-70

3.In the Group Name: field, enter the desired name.

4.In the TAC: field, enter the desired trunk access code.

5.In the Outgoing Display: field, enter y.

6.In the CESID I Digits Sent: field, enter the number directed by the Central Office (CO) or the Public Safety Answering Point (PSAP).

7.Scroll to page 3 of the form.

Page 3 of 11

TRUNK GROUP

ADMINISTRABLE TIMERS

Outgoing Disconnect (msec): 400

Cama Outgoing Dial Guard (msec): 75

Outgoing Glare Guard (msec): 1000

Cama Wink Start Time (msec): 5000

Outgoing End of Dial (sec): 1 Outgoing Seizure Response (sec): 4

Disconnect Signal Error (sec): 30

Screen 1-5. Administrable Timers form (page 3)

8.On the Administrable Timers screen (page 3), you may need to adjust these fields according to your CO. Scroll to page 5.

Page 78
Image 78
Lucent Technologies 555-230-128 manual Screen 1-5. Administrable Timers form, Trunk Group Administrable Timers