DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Install Equipment Room Hardware

Page 1-34

 

 

Circuit Pack Slot Loading

In general, load the circuit packs so that the number in each cabinet is about equal and the trunks and lines are evenly distributed among the cabinets. See Figure 1-18.

1.Install the TN798 Processor circuit pack in slot 1 of Cabinet A.

2.Install the TN2182B Tone-Clock circuit pack in slot 2 of Cabinet A.

Load all port circuit packs starting with Cabinet A first, Cabinet B next, and so forth. Return to Cabinet A and repeat.

3.A TN744D Call Classifier/Tone Detector circuit pack may be required in systems with heavy traffic. Install the TN744D into any port slot. Slot 1 of Cabinet B is preferred.

4.See Table 1-3 for the recommended circuit pack layout for the control carrier and the port carriers.

Page 42
Image 42
Lucent Technologies 555-230-128 manual Circuit Pack Slot Loading