1 Install and Cable the Cabinets

 

Install and Wire Telephones and Other Equipment

Page 1-61

 

 

DS1 Tie Trunk Example

DS1 tie trunks provide a 1.544 Mbps (T1) or 2.048 Mbps (E1) digital data service between 2 collocated systems or between the system and a data network. The following cables can be used:

C6C connector cable 50-foot (15.2 m) shielded cable with a 50-pin male connector on 1 end and a 15-pin male connector on the other end. Use to connect a DS1 tie trunk circuit pack to a Channel Service Unit.

C6D connector cable 50-foot (15.2 m) shielded cable with a 50-pin male connector on each end. Use to connect a DS1 tie trunks in collocated cabinets.

C6E connector cable 100-foot (30.5 m) shielded cable with a 50-pin male connector on 1 end and a 50-pin female connector on the other end. Use as an “extension” cable between the DS1 tie trunk circuit pack and other connector cables.

C6F connector cable 50-foot (15.2 m) shielded cable with a 50-pin male connector on 1 end and a 3 inch (7.62 cm) stub on the other end. Use to connect the DS1 tie trunk circuit pack to channel multiplexers requiring hardwired connections. See Table 1-8 for a pinout.

Table 1-8. Pinout of C6F Cable

 

 

Pin

Wire Color

Lead Designation

Number

 

 

 

 

White/Green

LI (High Side)

47

 

 

 

 

 

Green

LI

22

 

 

 

 

 

White/Brown

LO

48

 

 

 

 

 

Brown

LO (High Side)

23

 

 

 

 

 

White/Slate

LBACK2

49

 

 

 

 

 

Slate

LBACK1

24

 

 

 

 

 

 

 

 

 

Collocated DS1 Tie Trunks

Two DS1 tie trunk circuit packs can be in collocated systems. A DS1 tie trunk circuit pack in 1 system can connect to a DS1 tie trunk in another system. Use a C6D cable if the distance is less than 50 feet (15.24 m). If the distance is greater than 50 feet (15.24 m), use a C6E cable.

NOTE:

The maximum distance between cabinets is 1310 feet (399.3 m).

Page 69