DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Install and Wire Telephones and Other Equipment

Page 1-66

 

 

Install Attendant Console — Optional

1.Position the attendant console in the desired location and connect the modular cord to the information outlet.

2.Install labels per the Attendant Console form and Display Module form assignments.

3.Install a Digital Line circuit pack in the assigned carrier slot (if required).

4.Administer the Attendant Console forms in DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.

Hard-Wire Bridging

! CAUTION:

Bridging or paralleling these endpoints can cause electrical damage to the consoles or cause the circuit pack to remove power from the consoles.

Analog type hard-wire bridging is not allowed for 4-wire (only) DCP endpoints. This is because hard-wire bridging provides no way of combining the digital output of 2 bridged DCP sets. Also, a bridged endpoint causes the added load to degrade the DCP signal.

Dual Wiring of 2-Wire and 4-Wire Endpoints

Do not simultaneously wire a 2-wire and 4-wire endpoint to the same equipment location in an MDF, even though they connect to different colored wire pairs. The system uses separate circuit packs to interface 2- and 4-wire endpoints, and none are capable of interfacing both.

Install 26B1 Selector Console — Optional

1.Connect the supplied 3-foot (0.9 m) D8AC cable to the modular jack on the bottom of the 26B1 Selector Console.

2.Route the cable to the attendant console and connect to the DXS/BLF jack.

3.Attach labels according to the Attendant Console form.

4.Administer the console using DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.

Page 74
Image 74
Lucent Technologies 555-230-128 manual Install Attendant Console Optional, Hard-Wire Bridging