DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Activate and Administer the System

Page 1-48

 

 

Set Country Options

Some country options need to be set to turn off the red alarm LEDs.

1.Enter change system-parameters country options and press Enter. A screen similar to Screen 1-1 displays on the terminal. The cursor is set on the Companding Mode field.

Screen 1-1. Typical System Parameters Country-Options Screen

2.The default (United States) companding mode is mu-Law. If the country uses A-Law companding, type A-Law. Press Enter when finished.

NOTE:

Other items eventually need to be entered on this screen, but this is all that is needed to turn the red alarm LEDs off.

3.Set the country codes as needed in the following fields. Refer to Table 1-5 for the country codes. The United States country code (1) is shown in the example above.

Digital Loss Plan:

Analog Ringing Cadence:

Analog Line Transmission: