DEFINITY Enterprise Communications Server Release 6

Issue 3

Installation and Test for Compact Modular Cabinets 555-230-128

May 1998

1 Install and Cable the Cabinets

 

Install and Wire Telephones and Other Equipment

Page 1-58

 

 

Analog Station or 2-Wire Digital Station Example

This example is typical of the 2-wire digital stations,2-wire analog stations, analog CO trunks, DID trunks, and external alarms. See Figure 1-27.

T 2 28 T3

R 3 03 R3

2500wire RBP 040596

Figure Notes

1. 2500-type analog station

2. 2-wire analog line circuit pack

Figure 1-27. 2500-Type Analog Telephone Wiring

1.Choose a peripheral to connect (such as a 2-wire digital station).

2.Choose the port circuit pack to use and its carrier and slot number. For example, TN2183 Analog Line, Cabinet 1, Carrier C, Slot 1.

3.Choose a port circuit on the port circuit pack, for example port 3.

4.Install cross-connect jumpers to connect the pins from the 2-wire station to the appropriate pins on the port circuit pack.

5.Administer using DEFINITY Enterprise Communications Server Release 6 Administration and Feature Description.

Page 66
Image 66
Lucent Technologies 555-230-128 manual Analog Station or 2-Wire Digital Station Example