1 Install and Cable the Cabinets

 

 

Install and Wire Telephones and Other Equipment

Page 1-56

 

 

 

 

 

 

 

 

TXT 1

39 TXT5

TXR 2

14 TXR5

PXT 3

40

PXT5

PXR 6

15

PXR5

7

 

 

8

 

 

 

302cwire RPY 012098

Figure Notes

 

 

1.

302C1 attendant console

3.

-48 VDC from adjunct power

2.

4-wire digital line circuit pack

4.

Ground from adjunct power

Figure 1-25. 302C1 to TN754B Wiring

4.Install cross-connect jumpers to wire the terminal to the port circuit pack. See Figure 1-25. This pinout is for a 4-wire Digital Line circuit pack.