Chapter 7: Magnum Router GUI Manager
___________________________________________________________________
DLCI State Information
As seen in the above screen, the Detailed Port Information screen reports DLCI’s that have been either programmed or reported on the port specified in the Port dropdown box. The possible states for a DLCI are:
Configured, Reported and Active:
The DLCI is up and operational
Configured, NOT Reported and Active:
The DLCI has been configured, but is currently down
Configured, NOT Reported and NOT Active:
The DLCI has not been configured into the Magnum Router, and is waiting for a connection.
In cases where the Magnum Router port has been configured to work as a frame relay network port (supplies all required frame relay information), then all DLCI’s for that port will show Configured, Reported and Active. This DOES NOT mean that the DLCI is passing data. It just means that the DLCI is being sent out the selected port.