Chapter 12: Marathon Port Configuration
___________________________________________________________________
Chapter 12: Marathon Port Configuration
Frame Relay Port Configuration Example
NOTE: Bolded text items are fields that either need to be changed or are recommended that they be changed.
PORT CONFIGURATION [FRAME RELAY LINK]: 1. ASYNC
2. SYNC
3. INTERCONNECT LINK
4. SECONDARY INTERCONNECT LINK
5. FRAME RELAY LINK
FRAME RELAY LINK PARAMETERS [LEFT/ A01] |
|
1. CLOCK SPEED | [64000] |
2. PORT CLOCKING | |
3. MAXIMUM FRAME SIZE | [1500] |
4.NETWORK ADDRESS
5.LOCAL MANAGEMENT PROTOCOL [ANNEX D]
(LEAVE ALL THESE SETTINGS ALONE)
LOCAL MANAGEMENT PROTOCOL PARAMETERS [LEFT/ A01]
1. FULL STATUS POLLING COUNTER (N391) | [ | 6] |
2. ERROR THRESHOLD (N392) | [ 3] | |
3. MONITORED EVENTS COUNT (N393) | [ 4] | |
4. LINK INTEGRITY VERIFICATION TIMER (T391) | [10] | |
5. POLLING VERIFICATION TIMER (T392) | [15] | |
6. ACCESS LINK MODE | [USER] | |
DLCI PARAMETERS [A01.0053] |
|
|
1. COMMITTED BURST SIZE FORWARD (BC.FWD) | [ | 0] |
2. COMMITTED BURST SIZE BACKWARD (BC.BWD) [ | 0] | |
3. EXCESS BURST SIZE FORWARD (BE.FWD) | [ | 0] |
4. EXCESS BURST SIZE BACKWARD (BE.BWD) | [ | 0] |
5. CIR FORWARD (CIR.FWD) (BPS) | [ 128000] | |
6. CIR BACKWARD (CIR.BWD) (BPS) | [ 128000] | |
7. CONGESTION CONTROL | [ENABLE] |