Chapter 12: Marathon Port Configuration

___________________________________________________________________

Chapter 12: Marathon Port Configuration

Frame Relay Port Configuration Example

NOTE: Bolded text items are fields that either need to be changed or are recommended that they be changed.

PORT CONFIGURATION [FRAME RELAY LINK]: 1. ASYNC

2. SYNC

3. INTERCONNECT LINK

4. SECONDARY INTERCONNECT LINK

5. FRAME RELAY LINK

FRAME RELAY LINK PARAMETERS [LEFT/ A01]

 

1. CLOCK SPEED

[64000]

2. PORT CLOCKING

[TX-EXTERNAL/RX-EXTERNAL]

3. MAXIMUM FRAME SIZE

[1500]

4.NETWORK ADDRESS

5.LOCAL MANAGEMENT PROTOCOL [ANNEX D]

(LEAVE ALL THESE SETTINGS ALONE)

LOCAL MANAGEMENT PROTOCOL PARAMETERS [LEFT/ A01]

1. FULL STATUS POLLING COUNTER (N391)

[

6]

2. ERROR THRESHOLD (N392)

[ 3]

3. MONITORED EVENTS COUNT (N393)

[ 4]

4. LINK INTEGRITY VERIFICATION TIMER (T391)

[10]

5. POLLING VERIFICATION TIMER (T392)

[15]

6. ACCESS LINK MODE

[USER]

DLCI PARAMETERS [A01.0053]

 

 

1. COMMITTED BURST SIZE FORWARD (BC.FWD)

[

0]

2. COMMITTED BURST SIZE BACKWARD (BC.BWD) [

0]

3. EXCESS BURST SIZE FORWARD (BE.FWD)

[

0]

4. EXCESS BURST SIZE BACKWARD (BE.BWD)

[

0]

5. CIR FORWARD (CIR.FWD) (BPS)

[ 128000]

6. CIR BACKWARD (CIR.BWD) (BPS)

[ 128000]

7. CONGESTION CONTROL

[ENABLE]