MVoIP Requirements
The requirements to add an MVoIP entry include an entry in the WAN configuration using a DLCI of 900 thru 989 and an output port of E1; a WAN IP Route Map entry that uses a DLCI from 900 thru 989, and an Ethernet Configuration entry. If any of these requirements are not met, the Magnum Router Manager will report an error if the MVoIP button is clicked. One such error is displayed below:
Adding an MVoIP Entry
To add an entry in the MVoIP screen, perform the following steps:
1.Click New Entry or press
2.Select the MVoIP DLCI from the dropdown box, enter data in the Source IP Address and the destination IP Address
3.Click Save Edit or press
4.Click Exit Edit or press
Changing an MVoIP Entry
It is possible to change an entry after it has been entered into the table. Follow these steps to change an entry:
1.
This will cause all of the entry data to be loaded in the fields above the table.
2.Make any modifications required
3.Click on Save Edit or press
4.Clock on Exit Edit or press
If this entry was selected by mistake and is not the one that needed modification, just click on the Exit Edit or press
Deleting an MVoIP Entry
In some cases, an entry may need to be deleted. To do this, follow these steps:
1.Select an entry in the table.
2.Either click the Delete Entry button or press
3.A verification question is asked to make sure that this is the entry to delete, if it is, select Yes. Selecting No will return to the MVoIP screen.
Repeat for each entry that is to be deleted.