5

MCECC

HITDIS This bit controls a function that is not currently used in the

MCECC.

RADATA This bit controls a function that is not currently used in the

MCECC.

RACODE This bit controls a function that is not currently used in the

MCECC.

Scrub Period Register Bits 15-8

The Scrub Period Control Register controls how often a scrub of the entire memory is performed if the SCRBEN bit is set in the Scrub Control Register. The time between scrubs is approximately two seconds times the value programmed into the Scrub Period Register. The scrub period can be programmed from once every four seconds to once every 36 hours. This register contains bits 15-8 of the Scrub Period Register.

ADR/SIZ

 

1st $FFF43028/2nd $FFF43128 (8-bits)

 

 

 

 

 

 

 

 

 

 

 

BIT

31

30

29

28

27

26

25

24

 

 

 

 

 

 

 

 

 

NAME

SBPD15

SBPD14

SBPD13

SBPD12

SBPD11

SBPD10

SBPD9

SBPD8

 

 

 

 

 

 

 

 

 

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

 

 

 

 

 

 

 

 

 

RESET

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

 

 

 

 

 

 

 

 

 

Scrub Period Register Bits 7-0

This register contains bits 7-0 of the Scrub Period Register.

ADR/SIZ

 

1st $FFF4302C/2nd $FFF4312C (8-bits)

 

 

 

 

 

 

 

 

 

 

BIT

31

30

29

28

27

26

25

24

 

 

 

 

 

 

 

 

 

NAME

SBPD7

SBPD67

SBPD5

SBPD4

SBPD3

SBPD2

SBPD1

SBPD0

 

 

 

 

 

 

 

 

 

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

 

 

 

 

 

 

 

 

 

RESET

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

1 PLS

 

 

 

 

 

 

 

 

 