5

MCECC

Scrub Prescaler Counter (Bits 15-8)

This register reflects the current value in the scrub prescaler bits 15-8.

ADR/SIZ

 

1st $FFF4303C/2nd $FFF4313C (8-bits)

 

 

 

 

 

 

 

 

 

 

BIT

31

30

29

28

27

26

25

24

 

 

 

 

 

 

 

 

 

NAME

SPS15

SPS14

SPS13

SPS12

SPS11

SPS10

SPS9

SPS8

 

 

 

 

 

 

 

 

 

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

 

 

 

 

 

 

 

 

 

RESET

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

 

 

 

 

 

 

 

 

 

Scrub Prescaler Counter (Bits 7-0)

This register reflects the current value in the scrub prescaler bits 7-0.

ADR/SIZ

 

 

1st $FFF43040/2nd $FFF43140 (8-bits)

 

 

 

 

 

 

 

 

 

 

 

BIT

31

30

 

29

28

27

26

25

24

 

 

 

 

 

 

 

 

 

 

NAME

SPS7

SPS6

 

SPS5

SPS4

SPS3

SPS2

SPS1

SPS0

 

 

 

 

 

 

 

 

 

 

OPER

R/W

R/W

 

R/W

R/W

R/W

R/W

R/W

R/W

 

 

 

 

 

 

 

 

 

 

RESET

0 PLS

0 PLS

 

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

 

 

 

 

 

 

 

 

 

 

Scrub Timer Counter (Bits 15-8)

This read/write register is the Scrub Timer Counter. If scrubbing is enabled and the Scrub Period Register is non-zero, the Scrub Timer Counter increments approximately once every two seconds until it matches the value programmed into the Scrub Period Register, at which time, it clears and resumes incrementing. Writes to this address update the Scrub Timer Counter, reads to this address yield its value. The ability to read and write this register is provided for test purposes. Programming this counter is not recommended. This register reflects the current value in the Scrub Timer Counter bits 15-8.

5-28

Computer Group Literature Center Web Site

Page 318
Image 318
Motorola MVME172 manual Scrub Timer Counter Bits