Board Description and Memory Maps

Status:

Bit 7 of the MPU Status and DMA Interrupt Count Register, (actually in the DMAC Status Register) at address $FFF40048.

Comments:

The local bus timer timed out. This usually indicates the MPU tried to read or write an address at which there was no resource. Otherwise, it indicates a hardware problem.

DMAC VMEbus Error

Description:

The DMAC experienced a VMEbus error during an attempted transfer.

MPU Notification:

DMAC interrupt (when enabled).

Status:

The VME bit is set in the DMAC Status Register (address $FFF40048 bit 1).

Comments:

This indicates the DMAC attempted to access a VMEbus address at which there was no resource or the VMEbus slave returned a BERR signal.

DMAC Parity Error

Note The 400/500-Series MVME172 models do not contain parity DRAM.

Description:

Parity error while the DMAC was reading DRAM.

MPU Notification:

DMAC interrupt (when enabled).

Status:

The DLPE bit is set in the DMAC Status Register (address $FFF40048 bit 5).