Motorola MVME172 manual DMA Control Register

Models: MVME172

1 354
Download 354 pages 60.32 Kb
Page 273
Image 273

Programming Model

DMA Control Register 1

The registers which control IP_c and IP_d are not used on the 200/300- Series MVME172.

ADR/SIZ

 

$FFFBC024, $3C, $54, $6C (8 bits each)

 

 

 

 

 

 

 

 

 

 

BIT

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

NAME

DHALT

0

DTBL

ADMA

WIDTH1

WIDTH0

A_CH1

XXX

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

C_CH1

 

 

 

 

 

 

 

 

 

 

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

 

 

 

 

 

 

 

 

 

RESET

0 R

0 R

0 R

0 R

0 R

0 R

0 R

0R

 

 

 

 

 

 

 

 

 

XXXThis bit must remain cleared. If it is set to a one, the IP2 chip ASIC will not function correctly.

A_CH1, When A_CH1 is set to a zero, DMA request 0 from

C_CH1 Industry Pack b is associated with DMACb register set. When it is set to a one, DMA request 1 from Industry Pack a is associated with DMACb register set. When C_CH1 is set to a zero, DMA request 0 from Industry Pack d is associated with DMACd register set. When it is set to a one, DMA request 1 from Industry Pack c is associated with DMACd register set. Note that DMACa register set is always associated with DMA request 0 from Industry Pack a and DMACc register set is always associated with DMA request 0 from Industry Pack c. Therefore these bit positions are not defined for these two register sets. Refer to the section on the Enable DMA Function for information and restrictions on the operation of A_CH1 and C_CH1.

WIDTH1- WIDTH bits specify the width of the IndustryPack

WIDTH0 interface at position a or position a_b. The following table defines the bit encoding. Note that these width control bits are independent of the width control bits in the General Control Registers. Also note that unlike the width control

4

http://www.mcg.mot.com/literature

4-37