M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

B. TS800/155 Standard Model

The TS800/155 supports most of the prevalent protocols in the 34-155 Mbps range. Support for a special protocol, which is not on the list, can be ordered after coordination with the factory. This model can be used for Open Protocol applications which ensures complete transparency (including all data in the range of 1-155 Mbps.) In this case, a maximum 2 dB of the power budget is lost.

Figure 1.3: TS800/155 Standard Model Panel Schematic

Back Panel Description

Table 3: TS800/155 Standard Model Back Panel Controls, Interfaces, and Indicators

Connectors

Power

Power source Terminal Block (Main or UPS).

 

AC power supply (100 to 240 Vac) or DC power

 

supply (24 to 60 Vdc)

Fiber optic

Fiber Optic interface for connection to the

 

peripheral equipment. The standard interface is MM

 

1310nm SC connector; other interfaces are available

 

upon request.

 

In model TS800/155-F with the fusion option, there

 

are two fiberoptic interface ports for connection to

 

the Fusion system; one primary and the other

 

redundant.

Remote monitor

Connection to the RSM. (The RSM has to be

 

ordered separately)

Management

Connection to 10Base-T SNMP management

 

interface. Pins 1,2: TX and 3,6 RX.

 

Pins (4,5) and (7,8) of this connector can be used

 

for dry contact purposes, for Airlink flag and F/O

 

flag alarms respectively

5