MRV Communications TS700/155, TS800/155, TS700/100, TS700/G user manual DS1 Toggles

Models: TS800/155 TS700/100 TS700/155 TS700/G

1 77
Download 77 pages 1.79 Kb
Page 16
Image 16

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

Selectors

Data Rate

Set the transmission rate of the transceiver (internal

(DIP Switch

(Toggles 1,2,3,4)

clock).

DS1 Toggles)

 

- Fast Ethernet: 1,2,3,4 OFF

-- shown in

 

- ATM/OC3/STM1:155 Mbps: 2,3,4 OFF, 1 ON

Figure 1.3and

 

- SMPTE 143 Mbps: 3,4 OFF, 1,2 ON

1.4

 

- E3: 34.368 Mbps1,2,4 OFF, 3 ON

 

 

- T3: 44.736 Mbps: 2,4 OFF, 1,3 ON

 

 

- OC1/STM0: 51.840 Mbps: 1,4 OFF, 2,3 ON

 

 

- Customized 1 : 4 OFF, 1,2,3 ON

 

 

- Customized 2 : 1,3,4 OFF, 2 ON

 

 

- Open Protocol: 1,2,3 OFF, 4 ON.

Selectors

Mode Select

Set the Operating Mode

(DIP Switch

(Toggles 1, 2, 3)

ALIGNMENT = Idle transmitted automatically

DS2 Toggles)

 

NORMAL = Signal received via the F/O port is

-- shown in

 

transmitted through the Airlink TX. Signal received

Figure 1.3 and

 

via the Airlink RX is transmitted through the F/O

1.4

 

TX.

 

 

LOOPBACK= Data received by the F/O RX is

 

 

directly returned through the F/O TX.

 

 

REMOTE LOOP = Loops the electrical RX to the

 

 

electrical TX and optical RX to the optical TX of the

 

 

remote unit.

 

 

ATTENUATION: The alignment signal is

 

 

attenuated (~20db) when the DIP switch toggle #3

 

 

is moved to ON position.(to use when the

 

 

installation distance is less than 200m only for

 

 

alignment mode). Switch back to OFF position for

 

 

normal mode.

 

Laser Power Off

Turning off laser TX when the DIP switch toggle is

 

(Toggle 4)

moved to ON

 

Fusion

This switch toggle enables working with MRV’s

 

(Toggle 5)

Fusion system (Built-in fusion option or switch

 

 

option). For additional information, see page 7.

 

 

Switch toggle 5 OFF: Fusion not Active (Disabled)

 

 

Switch toggle 5 ON: Fusion active (Enabled).

 

Window Heater

Used only with the heating option (To be specified

 

(Optional)

in the PO).

 

(Toggle 6)

Switch toggle 6 OFF: The heater is disabled

 

 

Switch toggle 5 ON: The heater is enabled.

 

IP address set up

When the Switch toggle is on OFF position, the

 

(Toggle 7)

TereScope’s IP address is the default one (shown on

 

 

the back panel label: 10.0.0.101). To set a new IP

 

 

address please refer to the “IP address setting

 

 

procedure for TereScope management card” file in

 

 

the Manuals CD. The new IP address is valid only

 

 

after the TereScope is powered off and on.

 

Control Mode

When the Dip Switch toggle #8 is on OFF position,

 

(Toggle 8)

the TereScope is in the HARDWARE mode, i.e. the

 

 

TereScope is controlled only by the TereScope itself

 

 

by means of the switches on its back panel.

 

 

When the Dip Switch toggle is on ON position, the

 

 

TereScope is in the SOFTWARE mode i.e. the

 

 

TereScope is controlled by the management

 

 

Software and various functions can be activated by

 

 

means of this management Software.

 

 

 

Note: Pins (4,5) and (7,8) of the management RJ45 connector can be used for dry contact purposes, for Airlink flag and F/O flag alarms respectively.