M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

2.While looking (see fig 6.9 below) through the telescope, rotate and tilt the TereScope to bring the telescope crosshairs on the left side (your right side) of the opposite TereScope.

Fig. 6.9: Telescope crosshair on the opposite TereScope

3.Tighten firmly 4 Bolts K and D in such a way that the aiming anchors (L1&L2) will be between the screws C and B.

Fine Alignment

The purpose of fine alignment is to position the center of the transmitted beam spot on the center of the TereScope receiver – in both directions (Fig 6.10). This is achieved by adjusting the horizontal and vertical motion screws (shown in Figure 6.11) until maximum power is received at the opposite TereScope.

H1

V1

Beam Cross Section

Transceiver

H2

V2

Figure 6.10: Front view – Transceiver at the middle of the beam cross section

Fine Alignment Vertical

Motion Screws

Fine Alignment

Horizontal Motion Screws

Figure 6.11: Fine Alignment Motion Screws

41

Page 51
Image 51
MRV Communications TS700/G, TS700/155, TS800/155, TS700/100 user manual Fine Alignment