M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

D. TS700/100 - Fast-Ethernet System

Figure 1.6: TS700/100 Model Back Panel

Back Panel Description

Table 4: TS700/100 Back Panel Controls, Interfaces, and Indicators

Connectors

 

Power

 

Power source Terminal Block (Main or UPS)

 

 

 

AC power supply (100 to 240 Vac) or DC power

 

 

 

supply (24 to 60 Vdc).

 

 

 

 

 

100Base-TX

 

Copper interface (RJ45) for STP cables.

 

 

 

MDI-X connection (TX: pins 3,6 and RX: pins 1,2).

 

 

 

Connection to the peripheral equipment.

 

 

 

This connector can be used for Power-over-Ethernet

 

 

 

(PoE) but only with the Low Voltage TereScope version

 

 

 

(TS100/A/FET/V3). The standard power for PoE is

 

 

 

36-57 Vdc. However, the TS700/100 can operate with

 

 

 

20-60 Vdc.

 

 

 

See appendix I.

 

 

 

 

 

Management

 

Connection to 10Base-T SNMP management

 

(Optional)

 

interface. (To be ordered separately)

 

 

 

 

 

Dry Contacts

 

There are 2 pairs of dry contact indicators available,

 

 

 

one for Air RX Link LED (Pins 1 and 2), and the

 

 

 

other for 100BaseT LED (Pins 3 and for). Dry

 

 

 

contacts are normally closed (25 ohms), and open in

 

 

 

an alarm condition

 

 

 

 

11

Page 21
Image 21
MRV Communications TS800/155, TS700/155, TS700/G user manual TS700/100 Fast-Ethernet System