M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l
Selectors | Mode of Operation | Set the Operating Mode |
| |
(DIP Switch | (Toggles 1, 2) | ALIGNMENT = Idle transmitted automatically |
| |
Toggles) |
| NORMAL = Signal received through the TP port is |
| |
shown in Figure |
| transmitted through the Airlink TX. Signal received |
| |
1.6 |
| through the Airlink RX is transmitted through the |
| |
|
| TP TX. |
| |
|
| LOOPBACK=The Data received by the TP RX is |
| |
|
| directly returned through the TP TX |
| |
|
|
|
| |
| IP address set up | Used only with the management option. When the | ||
| (for Mgt. option) | Switch toggle is on OFF position, the TereScope’s |
| |
| (Toggle 3) | IP address is the default one (shown on the back |
| |
|
| panel label: 10.0.0.101). To set a new IP address |
| |
|
| please refer to the “IP address setting procedure for |
| |
|
| TereScope management card” file in the Manuals |
| |
|
| CD. The new IP address is valid only after the |
| |
|
| TereScope is powered off and on. |
| |
|
|
|
| |
| Speed | Sets the TereScope to | ||
| (Toggle 4) | forced 100 mode: |
| |
|
| OFF : |
| |
|
|
|
|
|
|
|
|
|
|
Indicators | Air RX Link LED |
| Green LED indicates signal received by the Airlink | |
|
| receiver. Turns ON at the threshold level. | ||
display, |
|
|
|
|
LEDs) | Air RX Data LED |
| Yellow LED blinking indicates Data transfer via | |
|
|
| the Airlink receiver to the interface. | |
|
|
|
|
|
| TP RX Link LED |
| Green LED indicates Link established at the | |
|
|
| ||
|
|
| peripheral equipment. | |
|
|
|
|
|
| TP RX Data LED |
| Yellow LED blinking indicates Data transfered via | |
|
|
| the | |
|
|
|
|
|
| Optical Power 7- |
| Digital readout indicates the Optical Power level | |
| segment display |
| received by the Airlink receiver. | |
|
|
|
|
|
Alignment
Telescope
For fine alignment.
12